Magnetic level meter in the tank liquid level selection 2 points unexpectedly explained

We are familiar with the varieties of liquid level gauges many times, and with the vigorous development in recent years, the varieties of liquid level gauges have not only increased, but also new functions have been added. Therefore, many customers are very familiar with the selection of Magnetic level meter. However, as the working conditions become more and more complicated, many people forget to consider the necessary conditions on site. For example, magnetic flap level gauges are commonly used in tank liquid level measurement. The magnetic flap liquid level gauge is unexpectedly explained at 2 points in the tank liquid level selection.
Point: When the liquid level in the tank is not too full, or when the liquid level in the tank is larger than the range that needs to be measured in daily operation, the liquid level in the tank is given priority, and the upper and lower flanges can be opened. flange center distance. Because this can ensure the satisfaction of liquid level measurement. For example, once the customer did not select the liquid level range when selecting the model. After half a year, due to the on-site process requirements, the liquid level increased, but it could not meet the requirements, and had to replace the magnetic flap liquid with a new measurement range. Bit meter.
The second point: In many cases, customers will only provide the liquid level, and forget an important factor, that is, the structural space position of the on-site tank. For example, the length of the tank on site is 2 meters, the liquid level measurement range is 2 meters, and the selected magnetic flap level gauge flange center distance is 1 meter 9, but the problem that the site tank is only 5 cm from the ground is not considered. Because when the conventional magnetic flap liquid level gauge is made, the distance between the center of the lower flange and the lower end of the liquid level gauge (including the drain valve) is about 30 cm, and the site is only 5 cm, so it is not easy to operate at the site. At this time, this space must be considered, and necessary measures can be taken to reduce the lower space and extend the length of the upper end so as to allow the operation space at the bottom.
Although the above 2 points are not very common, they will also be encountered. Therefore, customers must understand the structure of the magnetic flap level gauge in order to make no mistakes in the selection. There will also be omissions. After all, some customers directly come to order and give parameters directly. Sometimes they are busy and may consult these very uncommon factors.

CATEGORIES

CONTACT US

Contact: Kevin

Phone: +8615189522935

Tel: +86-517-86800063

Whatsapp: +8615189522935

Email: sales@xfmeter.com

Add: No.118 HengyangNanRoad, Jinhu County, Huaian,Jiangsu, China